NSN Parts Associated with NSN 5925-01-388-5479 (5925013885479) of Circuit Breaker- Submit a Quote
NSN 5925-01-388-5479 is a type of Circuit Breaker component is now available in stock at One Click Purchasing. NSN codes are a unique numeric serial number assigned by the Defense Logistics Agency (DLA) for all items acquired, stocked, and circulated within the federal supply chain. With NSNs, identifying items is made much easier, ensuring simplified purchasing processes where customers can guarantee that they only procure exact items as necessary.
At One Click Purchasing, owned and operated by ASAP Semiconductor LLC, we prioritize the supply of high-quality, authenticated NSN parts with NSN 5925-01-388-5479 at competitive prices. With an extensive supply-chain network, we guarantee the fastest turnaround times in the industry and a 95% on-time delivery track record. If you would like to obtain a rapid quote for parts with the NSN 5925-01-388-5479, please complete the instant RFQ form below, and a dedicated representative will contact you shortly.
Information of NSN 5925-01-388-5479 (5925013885479)
Alternate NSN : 5925-01-388-5479 |
Manufacturers : vdo control systems inc , computer sciences corporation , ai tek instruments llc |
CAGE Code : 82227 , 51066 , 1XP56 |
Item Name : Circuit Breaker |
NIIN : 013885479 |
FSG Name : 59 Electrical and Electronic Equipment Components |
FSC Name : 5925 Circuit Breakers |
NCB Code : USA (01) |
Part Number's List for NSN 5925-01-388-5479, 5925013885479
Part No | Manufacturer | Item Name | RFQ |
---|---|---|---|
APGH-111-1-61-103-01 | Avl | ||
111-0400001 | Avl | ||
APGH-111-1-61-103-01 | Avl |
Product Details of NSN 5925013885479
MRC | Criteria | Characteristic |
---|---|---|
CQXF | Inclosure Protection Type For Which Designed | CORROSION RESISTANT AND MOISTURE RESISTANT AND SHOCKPROOF AND VIBRATIONPROOF |
THSD | Thread Series Designator | UNC |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 1.660 INCHES NOMINAL |
BBRJ | Special Handling Feature | MAGNETIC |
PKWT | Unpackaged Unit Weight | 6.600 OUNCES |
CPLM | Maximum Continuous Load Current Rating Per Pole | 10.0 AMPERES AC ALL LOCATIONS |
AKPX | Pole Quantity | 3 |
FREQ | Frequency In Hertz | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
TTQY | Terminal Type And Quantity | 6 TAB, SOLDER LUG |
AJEC | Boss Height | 0.130 INCHES NOMINAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
FEAT | Special Features | BLACK HANDLE WITH WHITE MARKINGS |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.750 INCHES NOMINAL |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
AXHR | Mounting Facility Type And Quantity | 6 THREADED HOLE |
CPRX | Actuator Position Designation | AT EACH POLE |
CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
ADAT | Body Width | 2.265 INCHES MAXIMUM |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CPRW | Actuator Function | TRIP-RESET |
CQJX | Nominal Thread Size | 0.138 INCHES |
ADTV | Case Material | PLASTIC |
AJWX | Mounting Surface To Terminal End Distance | 2.000 INCHES MAXIMUM |
ADAQ | Body Length | 2.000 INCHES NOMINAL |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.530 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
CMLP | Thread Quantity Per Inch | 32 |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
MRC | Decoded Requirement | Clear Text Reply |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |