NSN Parts Associated with NSN 5985-01-339-9111 (5985013399111) of Adapter Waveguide- Submit a Quote
NSN 5985-01-339-9111 is a type of Adapter Waveguide component is now available in stock at One Click Purchasing. NSN codes are a unique numeric serial number assigned by the Defense Logistics Agency (DLA) for all items acquired, stocked, and circulated within the federal supply chain. With NSNs, identifying items is made much easier, ensuring simplified purchasing processes where customers can guarantee that they only procure exact items as necessary.
At One Click Purchasing, owned and operated by ASAP Semiconductor LLC, we prioritize the supply of high-quality, authenticated NSN parts with NSN 5985-01-339-9111 at competitive prices. With an extensive supply-chain network, we guarantee the fastest turnaround times in the industry and a 95% on-time delivery track record. If you would like to obtain a rapid quote for parts with the NSN 5985-01-339-9111, please complete the instant RFQ form below, and a dedicated representative will contact you shortly.
Information of NSN 5985-01-339-9111 (5985013399111)
Alternate NSN : 5985-01-339-9111 |
Manufacturers : tru inc , microtech inc , maury microwave corp , keysight technologies inc , emerson network power ltd , cobham electronic systems inc |
CAGE Code : 92180 , 54647 , 13047 , 52708 , 34078 , 96341 |
Item Name : Adapter Waveguide |
NIIN : 013399111 |
FSG Name : 59 Electrical and Electronic Equipment Components |
FSC Name : 5985 Antennas Waveguides and Related Equipment |
NCB Code : USA (01) |
Part Number's List for NSN 5985-01-339-9111, 5985013399111
Part No | Manufacturer | Item Name | RFQ |
---|---|---|---|
1324AS305-5 | Avl | ||
1324AS305-5 | Avl | ||
1324AS305-5 | Avl | ||
1324AS305-5 | Avl | ||
1324AS305-5 | Avl | ||
1324AS305-5 | Avl |
Product Details of NSN 5985013399111
MRC | Criteria | Characteristic |
---|---|---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR DOUBLE RIDGED EXTERNAL, RECTANGULAR DOUBLE INDENTED |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
AHSF | FLANGE QUANTITY | 1 |
AHSX | FLANGE INSIDE WIDTH | 0.795 INCHES MINIMUM SINGLE FLANGE AND 0.799 INCHES MAXIMUM SINGLE FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.360 INCHES MINIMUM SINGLE FLANGE AND 1.390 INCHES MAXIMUM SINGLE FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.360 INCHES MINIMUM SINGLE FLANGE AND 1.390 INCHES MAXIMUM SINGLE FLANGE |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.114 INCHES MINIMUM SINGLE FLANGE FIRST CONNECTION FACILITY AND 0.118 INCHES MAXIMUM SINGLE FLANGE FIRST CONNECTION FACILITY0.095 INCHES MINIMUM SINGLE FLANGE SECOND CONNECTION FACILITY AND 0.096 INCHES MAXIMUM SINGLE FLANGE SECOND CONNECT |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.30 |
AHUD | CONNECTOR END DESIGN | MALE |
BBPN | ADAPTER LENGTH | 1.340 INCHES MAXIMUM |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 0.789 INCHES MINIMUM AND 0.794 INCHES MAXIMUM |
CRFH | WAVEGUIDE INSIDE WIDTH | 0.689 INCHES MINIMUM AND 0.694 INCHES MAXIMUM |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.318 INCHES MINIMUM AND 0.324 INCHES MAXIMUM |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.418 INCHES MINIMUM AND 0.424 INCHES MAXIMUM |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE SINGLE FLANGE FIRST CONNECTION FACILITY2 UNTHREADED HOLE SINGLE FLANGE SECOND CONNECTION FACILITY |
CWBQ | ADAPTER OVERALL HEIGHT | 2.040 INCHES MAXIMUM |
CXBH | ADAPTER OVERALL WIDTH | 1.360 INCHES MINIMUM AND 1.390 INCHES MAXIMUM |
MATT | MATERIAL | ALUMINUM ALLOY SINGLE TUBING SEGMENT AND FLANGE |
ZZZV | FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIP. |
AHTD | FLANGE DEPTH | 0.173 INCHES MINIMUM SINGLE FLANGE AND 0.203 INCHES MAXIMUM SINGLE FLANGE |
AHTX | INSERTION LOSS IN DECIBELS | 0.30 |
CTCJ | FLANGE STYLE | CONTACT, DOUBLE RIDGE TYPE SINGLE FLANGE |
STYL | III STYLE DESIGNATOR | WAVEGUIDE TO COAXIAL |
AHSY | FLANGE INSIDE HEIGHT | 0.425 INCHES MINIMUM SINGLE FLANGE AND 0.429 INCHES MAXIMUM SINGLE FLANGE |
BBPQ | ADAPTER HEIGHT | 1.360 INCHES MINIMUM AND 1.390 INCHES MAXIMUM |
AHUC | COAXIAL CONNECTOR SERIES DESIGNATION | N |
SFTT | SURFACE TREATMENT | CHROMATE SINGLE TUBING SEGMENT AND FLANGE INSIDE SURFACESPAINT SINGLE TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |